APC Back-UPS Pro, 1000VA/600W, Tower, 230V, 6x India 6A outlets, AVR, LCD, User Replaceable Battery

Ask for Discount

Include country code. E.g. +91 for India.
Provide as much details as possible

Description

This product is part of the Back-UPS Pro range. This 1000VA battery backup UPS has 8 total outlets, 4 outlets provide UPS power backup and surge protection, 4 outlets offer surge protection only. It features a built-in AVR and a LCD interface with audible alarms. Its runtime at 100 Watts is 56.7 minutes. Its dimensions are 30.1 x 11.4 x 38.2 cm and 11.35 kg. The Back-UPS Pro family offers guaranteed power protection for high-performance computer systems, routers, external storage devices, game consoles, and other home and business electronics.

Main
Run time for load 600 W: 6min 27s
Max. Capacity Used: 100 %
Main Input Voltage: 230 V
Rated power in W: 600 W
Rated power in VA: 1000 VA
Product or component type: Uninterruptible power supply (UPS)
Output connection type: 4 India 3-pin 6A, 2 India 3-pin 6A surge
Cable length: 1.52 m
Number of cables: 1
Battery type: Lead-acid battery

Batteries & Runtime
Number of battery-filled slots: 0
Number of battery-free slots: 0
Battery recharge time: 7.4 h
Number of battery replacement quantity: 1
Battery charger power: 29 W rated
Battery power in VAH: 216 VAh runtime
Battery life: 2…4 year(s)
Replacement battery: APCRBC124, APCRBC144
Battery option: BR24BPG-IN 1 432 VAh
Extended runtime: 1

Physical
Colour: Black
Height: 30.1 cm
Width: 11.4 cm
Depth: 38.2 cm
Product weight: 11.35 kg
Mounting preference: No preference
Mounting mode: Not rack-mountable
Two post mountable: 0
USB compatible: No

Input
Network frequency: 50/60 Hz +/- 3 Hz auto-sensing
Plug standard: India 3-pin 6A
Input voltage limits: 170…294 V

Output
Maximum configurable power in W” 600 W
Output frequency: 50/60 Hz +/- 1 Hz sync to mains
UPS type: Line interactive
Wave type: Stepped approximation to a sinewave
Efficiency: 84 % (full load) 80 % (half load)
Maximum configurable power in VA: 1000 VA
Transfer time: 8 ms typical, 12 ms maximum

Communications & Management
Control panel: Multifunction LCD status and control console
Alarm: Alarm when on battery, distinctive low battery alarm, overload continuous tone alarm